Why are stopped-flow methods not suitable for reactions with extremely short half-lives?
Stopped-flow methods are not suitable for reactions with extremely short half-lives because they are limited by the time required to mix the reactants. In this technique, reactants are forced into a reaction chamber and the flow is suddenly stopped to measure the amounts of substances present.1
Because the mixing process itself takes a finite amount of time, these methods cannot accurately measure reactions with a half-life of less than approximately one-hundredth of a second. When a reaction occurs faster than the time it takes to complete the mixing, the initial state of the reaction cannot be determined, rendering the measurement unreliable. For processes occurring on faster timescales, researchers instead utilize pulse and probe methods, such as flash-photolysis or relaxation methods, which bypass the physical limitations of mechanical mixing.1